Junction modules

1750 Modules

$

  • signal and low current distribution
  • many contacts layouts (even mixed)
  • modules from 6 to 36 contacts, sizes 10 to 22
  • 26 to 8 AWG for cable sections from 0,15 to 8,98 mm²
  • mounting on composite or metallic rail
  • sealing assured by a patended overmoulded grommet
  • in/out the rail without special tools nor adjacent modules removing
  • contacts : NF/UTE L53-105 - NAS 1749 & EN 3155-016

1767 PA Modules with 'Positive Locking'

$

  • Same performances as 1750 modules. Besides :
  • 100% guarantee of properly contact locking : PA technology prevents contacts from being unsecurely locked in position, and then from becoming faulty while in service.
  • wire pulling tests becomes unnecessary with PA modules
  • weight of modules reduced about 50 %
  • contacts : NF/UTE L53-105 - NAS 1749 & EN 3155-016
  • modules : derived from NF/UTE C 93-462

1100 Modules

$

  • to be fitted with male contacts EN3155-016
  • various contacts arrangements
  • contacts size : 22, 20, 16 and 12
  • 26 to 12 AWG for cable sections from 0,15 to 3,18 mm²
  • sealing assured by a patended overmoulded grommet
  • contacts : NF/UTE L53-105 - NAS 1749 & EN 3155-016
  • modules : NF/UTE C93-462

1200 Modules / ABS1569

$

  • to be fitted with female contacts EN3155-015
  • recommended in case of micro-intensity
  • contacts size : 20
  • 24 to 18 AWG for cable sections from 0,25 to 1 mm²
  • sealing assured by a patended overmoulded grommet

1400 Modules

$

  • contacts size : 22, 20 & 16, from 26 to 14 AWG
  • monobloc rails from 2 to 15 modules (feedback- & through-)
  • sealing assured by a patended overmoulded grommet
  • contacts : NF/UTE L53-105 - NAS 1749 & EN 3155-016
  • monobloc rails : NAS 1749 - NF/UTE C93-462 & PAN 6450-6451 PANAVIA

1765 Electronic Component Carrier Modules

$

    Same performances as 1750 modules. Besides :
  • components mounting means : solder pads, fuseholder clamps, inserted or welded directely on PCB
  • protection of components by a cover
  • components may be protected by resin or insulating foam
  • contacts : NF/UTE L53-105, NAS 1749 & EN 3155-016
  • modules : derived from NF/UTE C 93-462 standard

1777 Modules

$

  • signal and low current distribution
  • Compact design, alternative to Terminal Blocks
  • many contacts layouts (even mixed)
  • from 6 to 18 contacts, sizes 10 to 20
  • cable sections from 0,25 to 6 mm²
  • IP 66
  • in/out without special tools nor adjacent module removing
  • contacts : NF/UTE L53-105 & EN 3155-016
  • modules : NF/UTE C 93-462

1165 Modules for Nuclear Environment

$

  • qualified for K1 and K2 environment
  • suited to interconnect cables with different cross section
  • sealed
  • removable mini-modules / socket mounted on rail
  • contacts shunted by 2 or 3 contacts - mini-modules with 3 x 2 shunted contacts shuntés or 4 x 2 shunted contacts
  • cable cross section from 0,38 to 3,3 mm²
  • satisfy environmental test specification EDF / DER n° HM 63 - 7195/5 relating to class IE-A materials for PWR nuclear power stations
  • quick & easy maintenance

1600 Modules

$

  • modules of 6 or 8 contacts
  • many contacts layouts available
  • contacts from 16 to 12 AWG
  • contacts : NFL 53-105A - LN 65093 & NAS 1749